Lock Picking 101 Forum
A community dedicated to the fun and ethical hobby of lock picking.
       

Lock Picking 101 Home
Login
Profile
Members
Forum Rules
Frequent Forum Questions
SEARCH
View New Posts
View Active Topics


Live Chat on Discord
LP101 Forum Chat
Keypicking Forum Chat
Reddit r/lockpicking Chat



Learn How to Pick Locks
FAQs & General Questions
Got Beginner Questions?
Pick-Fu [Intermediate Level]


Ask a Locksmith
This Old Lock
This Old Safe
What Lock Should I Buy?



Hardware
Locks
Lock Patents
Lock Picks
Lock Bumping
Lock Impressioning
Lock Pick Guns, Snappers
European Locks & Picks
The Machine Shop
The Open Source Lock
Handcuffs


Member Spotlight
Member Introductions
Member Lock Collections
Member Social Media


Off Topic
General Chatter
Other Puzzles


Locksmith Business Info
Training & Licensing
Running a Business
Keyways & Key Blanks
Key Machines
Master Keyed Systems
Closers and Crash Bars
Life Safety Compliance
Electronic Locks & Access
Locksmith Supplies
Locksmith Lounge


Buy Sell Trade
Buy - Sell - Trade
It came from Ebay!


Advanced Topics
Membership Information
Special Access Required:
High Security Locks
Vending Locks
Advanced Lock Pick Tools
Bypass Techniques
Safes & Safe Locks
Automotive Entry & Tools
Advanced Buy/Sell/Trade


Locksport Groups
Locksport Local
Chapter President's Office
Locksport Board Room
 

bs lever lock pics

European hardware -lever locks, profile cylinders specific for European locks. European lock picks and European locks.

bs lever lock pics

Postby quicklocks » 12 May 2004 15:03

:oops:
Last edited by quicklocks on 30 Jun 2006 5:29, edited 1 time in total.
quicklocks
 
Posts: 1014
Joined: 10 Sep 2003 9:04

Postby Varjeal » 17 May 2004 18:31

I haven't seen the inside of too many lever locks, but I've seen enough to realize those are the nastiest false notches I've EVER seen. Man, that would really mess a person up.
*insert witty comment here*
Varjeal
Moderator Emeritus
 
Posts: 2869
Joined: 3 Oct 2003 15:05
Location: Western Canada

Postby Safekey » 18 May 2004 5:28

Image

Chubb detainers above.

Chubb levers below.

Image
Safekey
 
Posts: 49
Joined: 17 Apr 2004 8:47
Location: United Kingdom

Postby quicklocks » 18 May 2004 12:30

:D
Last edited by quicklocks on 23 Jun 2006 10:28, edited 1 time in total.
quicklocks
 
Posts: 1014
Joined: 10 Sep 2003 9:04

Postby Safekey » 18 May 2004 12:43

They are a bit on the large side :oops:
Safekey
 
Posts: 49
Joined: 17 Apr 2004 8:47
Location: United Kingdom

Postby Keyring » 18 May 2004 12:49

Image

Here's a UK 'Homebase' BS lever. Sorry about the crappy focus.
I only had a couple of minutes available.
What makes me wonder is that ALL the false notches in this lock
are on the wrong side of the real notch to do any good.
I suppose it depends on the height of the particular notches that
the key is set up for.
Keyring
 
Posts: 486
Joined: 23 Mar 2004 8:01
Location: uk

Postby quicklocks » 18 May 2004 15:37

:D
Last edited by quicklocks on 23 Jun 2006 10:28, edited 1 time in total.
quicklocks
 
Posts: 1014
Joined: 10 Sep 2003 9:04

Postby toomush2drink » 21 May 2004 16:27

Heres a few more to get your eyes around. First up is a union bs 5 lever look closely at the stump and you can see it has a notch as well as the levers. This isnt really an expensive lock either !!
Image
Image

This is a securefast mortice with the key in and half turned
Image
Image

enjoy
toomush2drink
 
Posts: 1966
Joined: 26 Mar 2004 15:56
Location: UK london

Postby Jlo » 22 May 2004 5:50

Hi,

I was interested to see the pictures of the chubb detainer lock. I know these differ from normal lever locks and are used on 'comercial' properties and offer many more key differs.

Can anyone explain why its more secure than a normal 5 lever bs lock as the detainers still seem to have a slot for the stump to go in to and its difficult to see but I am guessing there are shallow notches on the detaners as well. But then so have the levers on a lever lock so what is the difference?

Looking foward to the replies.

Kind Regards

Jlo
Jlo
 
Posts: 90
Joined: 19 Oct 2003 13:10
Location: UK (Worcestershire)

Postby Safekey » 22 May 2004 18:04

I will post a picture of a 3G110 detainer lock when Im next in shop.

Four examples for information:

3G110 (BS3621) = 5 Detainers and approx 25,000 differs Standard case size 73mm

3G114 (BS3621) = 5 Levers and apprx. 1000 differs, Case sizes 67mm & 80mm (The Staddon roller pick will work on this lock & 3G115)

3G135 = 5 Detainers and approx. 75,000 differs. Special key profile only available from Chubb. (Does NOT have British Standard !)

3K277 (BS3621) = 7 Levers with approx. 6000 differs, 20mm throw bolt.

Detainers offer more depth cuts, which in turn offer more key differs.
Key length and guage are also different for lever compared to detainer.
Detainers does not mean higher security, as the BS shows above.

Detainer locks are more common in commercial and lever to residential. Microswitches can be found in either for connection to alarm systems.
Safekey
 
Posts: 49
Joined: 17 Apr 2004 8:47
Location: United Kingdom

Postby toomush2drink » 23 May 2004 5:08

Is there anyway of telling if there is a microswitch present or is it just a case of asking the customer if it activates the alarm ? I can just imagine the grief one of these could get you into when drilling.
Last edited by toomush2drink on 23 May 2004 7:31, edited 2 times in total.
toomush2drink
 
Posts: 1966
Joined: 26 Mar 2004 15:56
Location: UK london

Postby Safekey » 23 May 2004 5:56

Generally the customer would know if the key/lock operated some kind of alarm trigger. A lot of hospital store rooms & nursing homes have them, especially where drugs or valuables may be kept. A simple alarm system can be used and the microswitch connected to the on/off. This saves time when the nurse/doctor needs urgent med stuff, but cannot afford to spend time switching off the alarm then back on again when leaving.

Dont know of any means to identify if a mortice lock has a microswitch installed. You could probably use one of those 'Wall Wire Locaters' Used to test for current before drilling into a wall. However, I dont know if these devices could detect that small of a current, especially within a lock case. :?:
Safekey
 
Posts: 49
Joined: 17 Apr 2004 8:47
Location: United Kingdom

Postby toomush2drink » 23 May 2004 7:33

I suppose we could do with one of those really thin probes with a camera in like the special forces use for surveillance.
toomush2drink
 
Posts: 1966
Joined: 26 Mar 2004 15:56
Location: UK london

Postby Romstar » 23 May 2004 11:46

toomush2drink wrote:I suppose we could do with one of those really thin probes with a camera in like the special forces use for surveillance.


Funny you mention that. I was thinking the exact same thing.
Image
Romstar
 
Posts: 2823
Joined: 18 Apr 2004 3:13
Location: Nova Scotia, Canada

Postby xlr8ed1 » 24 May 2004 2:49

those are some nice pics

for those not in the know the difference between the chubb and the ERA locks has to do with the stump. The chubb uses only a brass stump which can easily be forced across (brass being very soft.) The era uses a solid steel stump (just look at the pics) which makes it hard to force open - this was its main selling point.

You will also notice some of the levers have half mooned shaped machined off them. The reason for this is so that high cuts dont pick up the lever next them. Indeed if you ever cut a mortice key the high cuts are slways alittle thinner then deep cuts in order to allow the levers to fall into the deep cuts of the key. Some locks avoid this by putting little spacers inbetween the levers (like the ERA)

the problem with era locks (apart from being english made) is that the spring tension on the levers is very weak and can be easily picked with a modified key blank that will decode the lock (only five cuts) which if you have space and depth keys then a key can be made.
xlr8ed1
 
Posts: 99
Joined: 14 Apr 2004 21:07
Location: Austrailia

Next

Return to European Locks, Picks and Hardware

Who is online

Users browsing this forum: No registered users and 4 guests